MNR University: Clinical Research, Medical & Health Sciences

30 core concepts and 64 advanced concepts, each linked to the others it depends on.

Core concepts

The concepts this subject is built on, each with the mistake people actually make with it.

Pre-analytical, analytical and post-analytical

Errors occur in all three phases, and most occur in the first, before any machine is involved.

Where people go wrong

Investing only in analyser quality control.

Turn it into a study

Classify every error in your laboratory by phase.

Quality control and calibration

Controls check that the method is performing. Calibration sets it against a known value. They are not the same.

Where people go wrong

Running controls without acting when they drift.

Turn it into a study

out-of-control runs and what was done about them.

Turnaround time

Measured from collection to result reaching the clinician, not from when the sample arrived at the bench.

Where people go wrong

Measuring the part the laboratory controls and calling it the whole.

Turn it into a study

Measure each segment separately and find the slowest.

Critical values

Results needing immediate communication to a named person, with the handover documented.

Where people go wrong

Filing a critical result in the report rather than telephoning it.

Turn it into a study

how often critical values were communicated and how fast.

Know what the test measures

A technician who knows what an analyte means clinically recognises an implausible result, and one who does not reports it, which makes clinical knowledge part of technical competence.

Where people go wrong

Treating the analyser's output as the end of the task.

Turn it into a study

List the clinical meaning of your laboratory's ten commonest tests.

Units and reporting formats cause errors

The same analyte reported in different units between laboratories causes serious misinterpretation, which is why the unit is part of the result rather than a convention.

Where people go wrong

Reporting a value without its unit and .

Turn it into a study

Compare units used for one analyte across local laboratories.

Reference ranges are population-specific

A derived from one population may not suit another by age, sex, altitude or ethnicity, which affects who is called abnormal.

Where people go wrong

Using a manufacturer's range without local verification.

Turn it into a study

Verify one against local healthy samples.

Age and sex-specific ranges matter

Many analytes differ by age and sex enough that a single range misclassifies children, the elderly and one sex, which is why partitioned ranges exist.

Where people go wrong

Applying an adult range to a child's result.

Turn it into a study

Review which of your analytes have partitioned ranges.

Interference is specific and predictable

Lipaemia, icterus, haemolysis and specific drugs interfere with defined assays in defined directions, which can be anticipated rather than discovered.

Where people go wrong

Reporting an interfered result without a comment.

Turn it into a study

Tabulate interferences for your laboratory's main assays.

Linearity and the reportable range

An assay is reliable only within a validated range, and results beyond it must be diluted and repeated rather than reported as read.

Where people go wrong

Reporting a result above the assay's upper limit.

Turn it into a study

Review the reportable ranges for your assays.

Dilution has rules

A diluted sample's result must be multiplied correctly and the dilution recorded, and dilution errors produce results that are wrong by orders of magnitude.

Where people go wrong

Diluting without recording the factor.

Turn it into a study

dilution recording in your laboratory.

Microscopy is a declining skill

Blood film, urine and stool microscopy detect findings no automated analyser reports, and the skill is being lost as automation spreads.

Where people go wrong

Relying on analyser flags to detect what a film would show.

Turn it into a study

Review films from flagged samples and record additional findings.

Stains have a purpose and a control

Each stain demonstrates a specific structure, and a stain without a known positive control cannot be interpreted when it is negative.

Where people go wrong

Reporting a negative stain without a control.

Turn it into a study

control use for stains in your laboratory.

Culture plates are read in sequence

Colony morphology, haemolysis, growth on selective media and biochemical reactions are read in order, and skipping a step produces a wrong identification.

Where people go wrong

Identifying an organism from colony appearance alone.

Turn it into a study

Work through one identification documenting each step.

Antibiotic sensitivity testing has conditions

Disc diffusion results depend on inoculum density, medium depth, incubation time and disc storage, and departures from the standard change the zone sizes.

Where people go wrong

Reading zones without controlling the conditions.

Turn it into a study

your testing conditions against the standard.

Quality control organisms verify the method

Reference strains with known are tested alongside patients to verify the whole method, and a failed control invalidates the day's results.

Where people go wrong

Reporting results on a day the control failed.

Turn it into a study

Review control strain results in your laboratory.

The request form is the laboratory's history

Patient identity, clinical details, the test wanted and the time of collection are what the laboratory works from, and an incomplete form produces an uninterpretable result.

Where people go wrong

Sending a sample with identity details alone.

Turn it into a study

request form completeness in your laboratory.

Identity checking happens at the patient

A sample is labelled at the bedside after checking the patient's identity, because labelling elsewhere allows a correct result on the wrong patient.

Where people go wrong

Labelling tubes before or away from the patient.

Turn it into a study

Observe labelling practice at collection on your ward.

Rejection criteria protect the patient

A laboratory rejecting an inadequate sample prevents a misleading result, and pressure to process anything that arrives is pressure to report unreliable numbers.

Where people go wrong

Processing a sample that fails acceptance criteria with a comment.

Turn it into a study

Review rejection rates and reasons in your laboratory.

Standard precautions apply to every sample

Every specimen is handled as potentially infectious because status is unknown, which governs containers, transport, spills and personal protection.

Where people go wrong

Varying precautions by presumed patient status.

Turn it into a study

specimen transport containers in your hospital.

Biomedical waste has categories

India's rules assign waste to colour-coded categories with defined treatment, and misclassification is a regulatory breach with real environmental consequences.

Where people go wrong

Disposing of laboratory waste in general bins.

Turn it into a study

waste segregation in your laboratory.

Needlestick is an occupational exposure

A sharps injury requires immediate washing, reporting, risk assessment and in defined cases prophylaxis within hours, through a pathway that must work at night.

Where people go wrong

Managing a sharps injury informally.

Turn it into a study

Test your hospital's out-of-hours exposure pathway.

Equipment calibration has a schedule

Instruments drift, so calibration against traceable standards on a defined schedule is what keeps results comparable over time.

Where people go wrong

Calibrating when results look wrong.

Turn it into a study

Review calibration records for your laboratory equipment.

Reagent lots change results

A new reagent lot can shift results measurably, so lot-to-lot verification is performed before a new lot is used for patient samples.

Where people go wrong

Switching reagent lots without verification.

Turn it into a study

Review lot change verification records in your laboratory.

Turnaround time is measured from collection

The clinically relevant interval runs from when the sample was taken to when the result was seen, not from when the laboratory received it.

Where people go wrong

Measuring turnaround from receipt to result.

Turn it into a study

Measure full turnaround including transport and reporting.

Result entry errors are undetectable

A transcribed result cannot be checked against anything, which is why interfaced analysers and barcode identification remove a whole error class.

Where people go wrong

Transcribing results manually without a second check.

Turn it into a study

manual transcription steps in your laboratory workflow.

Records are retained by regulation

Laboratory, imaging and blood bank records have defined retention periods, and a result that cannot be retrieved is as useful as one never produced.

Where people go wrong

Discarding records by available storage space.

Turn it into a study

Review retention requirements for your records.

Patient contact is part of the technical role

Explaining a procedure, positioning a patient and recognising distress are part of every technical role, and the measurement depends on the patient's cooperation.

Where people go wrong

Treating technical work as separate from patient care.

Turn it into a study

Observe patient communication during technical procedures.

Scope of practice is defined

Each allied health cadre has a defined scope, and working beyond it exposes the practitioner and the patient, while working below it wastes capacity.

Where people go wrong

Assuming scope by custom rather than regulation.

Turn it into a study

Review the defined scope for your cadre.

Reporting an abnormal result is a duty

A technician noticing a critical or implausible result has a duty to escalate rather than report it without comment, which makes judgement part of the technical role.

Where people go wrong

Reporting a result that cannot be right.

Turn it into a study

Review escalation practice for implausible results in your laboratory.

Advanced concepts

Less often taught: each one questions a common assumption, connects this subject to another, and ends in a study you could run here.

Reference change value

The change between two results on the same person that exceeds analytical and biological variation. It answers whether a patient has really changed, which a cannot.

Where people go wrong

Comparing two serial results against the population , which was never designed for that question.

Turn it into a study

Compute the reference change value for a common analyte in your laboratory.

Biological variation

Every analyte varies within a person around their own set point, and that variation differs between analytes and sets how useful the test is for monitoring.

Where people go wrong

Treating every change as clinically meaningful.

Turn it into a study

Measure within-person variation for one analyte across repeated samples.

Delta checks

Comparing a result with the same patient's previous one, which catches sample mix-ups that look perfectly normal against the population range.

Where people go wrong

Validating results against the alone.

Turn it into a study

Implement a delta check and count the errors it catches.

Westgard rules

A set of control rules balancing error detection against false rejection, chosen according to how much error the test can tolerate.

Where people go wrong

Applying the same rules to every assay regardless of its performance requirement.

Turn it into a study

Select rules for one assay based on its sigma metric.

Sigma metrics

A single number combining allowable error, and imprecision, which says how much quality control an assay actually needs.

Where people go wrong

Running identical control schedules across assays of very different quality.

Turn it into a study

Compute sigma for your assays and set control frequency accordingly.

The hook effect

At very high analyte concentration some immunoassays give a falsely low or normal result, because excess antigen saturates both antibodies.

Where people go wrong

Reporting a normal result in a patient with obvious disease, when dilution would have revealed it.

Turn it into a study

Test a diluted series on an assay prone to the effect and document the hook.

Traceability and standardisation

Results are comparable between laboratories only if both are traceable to the same reference material, which many assays are not.

Where people go wrong

Comparing results across hospitals as though the number meant the same thing.

Turn it into a study

Compare the same samples across two laboratories and quantify the difference.

Point-of-care versus laboratory testing

Speed is bought with reduced analytical performance and less quality control, which is often the correct trade and sometimes not.

Where people go wrong

Assuming a point-of-care result is interchangeable with the laboratory one.

Turn it into a study

Compare paired point-of-care and laboratory results for one analyte.

Order of draw

Additives carry over between tubes, so the sequence of filling changes results, particularly potassium and coagulation tests.

Where people go wrong

Treating the order as a convention rather than as a source of real error.

Turn it into a study

order of draw and relate it to spurious results.

Autoverification

Rules releasing results automatically when they meet defined criteria, which speeds reporting and shifts the risk to how the rules were written.

Where people go wrong

Autoverifying without a delta check or a critical limit.

Turn it into a study

Review the autoverification rules in your laboratory and what they would let through.

Radiation protection as a system

Time, distance and shielding, with dose monitoring, applying to staff as much as to patients.

Where people go wrong

Treating the lead apron as the whole of protection.

Turn it into a study

staff dosimeter use and readings in your department.

Image quality against dose

More dose gives a cleaner image, so every protocol is a deliberate compromise rather than a technical optimum.

Where people go wrong

Raising exposure factors to improve appearance without reference to diagnostic need.

Turn it into a study

Compare image quality and dose across protocol settings for one examination.

Sterile technique as a measurable behaviour

Breaks in technique are observable and countable, which turns an attitude into an auditable process.

Where people go wrong

Treating asepsis as a matter of training alone.

Turn it into a study

Observe and count technique breaks during procedures in your unit.

The specimen journey

A sample passes through collection, transport, receipt, processing, analysis and reporting, and most error happens before analysis.

Where people go wrong

Investing quality effort where the analyser is rather than where the errors are.

Turn it into a study

Map the full journey and count errors at each stage.

The laboratory produces most of the record

A majority of entries in a patient's record are laboratory results, which makes laboratory quality a determinant of diagnosis across every specialty.

Where people go wrong

Treating the laboratory as a service rather than a diagnostic partner.

Turn it into a study

Count laboratory results against other entries in a patient record.

Most errors happen before the analyser

Collection, labelling, transport and handling account for the large majority of laboratory errors, while the analytical step is the most controlled part of the process.

Where people go wrong

Investing quality effort in the analyser.

Turn it into a study

Classify your laboratory's errors by phase.

Haemolysis is the commonest rejection reason

Haemolysed samples give false potassium, enzyme and bilirubin values, and the causes are collection technique rather than patient factors.

Where people go wrong

Reporting a haemolysed sample with a comment.

Turn it into a study

Measure your laboratory's haemolysis rate by collection area.

Tube additives determine the test

Each tube's additive suits specific analytes, and using the wrong tube or filling it inadequately changes the result rather than merely invalidating it.

Where people go wrong

Treating tube choice as a logistics matter.

Turn it into a study

tube selection errors in your laboratory.

Sample stability limits turnaround

Each analyte has a stability window after collection, outside which the result reflects storage rather than the patient, which sets transport requirements.

Where people go wrong

Running a delayed sample without qualification.

Turn it into a study

Review stability limits for your laboratory's common analytes.

Internal and external quality control differ

Internal control monitors a laboratory against itself over time; external comparison with other laboratories detects that internal control cannot see.

Where people go wrong

Relying on internal control alone.

Turn it into a study

Review your laboratory's external quality assessment results.

Accreditation is a system, not a certificate

Laboratory accreditation assesses the whole quality system including personnel, equipment, procedures and results, and maintaining it is continuous rather than episodic.

Where people go wrong

Treating accreditation as an inspection to pass.

Turn it into a study

Review your laboratory's accreditation standard requirements.

Verification before validation

A laboratory adopting a commercial method verifies its performance locally; developing a new method requires full validation, and the two have different requirements.

Where people go wrong

Adopting a method without local verification.

Turn it into a study

Review verification records for a recently adopted method.

Measurement uncertainty should be reported

Every result carries an uncertainty, and reporting it or at least knowing it prevents clinical decisions on differences smaller than the method can resolve.

Where people go wrong

Reporting results to more digits than the method supports.

Turn it into a study

Compute measurement uncertainty for one analyte.

Critical values need a closed loop

A critical result requires contacting a clinician, confirming receipt and documenting it, because a result in a system is not a result received.

Where people go wrong

Flagging a critical result in the system.

Turn it into a study

critical value notification and documentation.

Reflex and reflective testing

A laboratory can add tests automatically on a defined result, or a pathologist can add them on review, which shortens diagnostic pathways without extra requests.

Where people go wrong

Waiting for the clinician to request the obvious follow-up test.

Turn it into a study

Design a reflex testing rule for one abnormal result.

Demand management reduces useless testing

Minimum retest intervals, removing tests from order sets and requiring indications reduce unnecessary testing substantially without harming care.

Where people go wrong

Addressing over-testing through education alone.

Turn it into a study

Introduce a minimum retest interval for one test.

Daily blood tests cause anaemia

Repeated blood sampling in hospital removes enough blood to cause anaemia and transfusion, particularly in intensive care, which makes test frequency a clinical decision.

Where people go wrong

Ordering daily bloods as a default.

Turn it into a study

Measure blood volume drawn per patient per day in your unit.

Point-of-care testing shifts the error profile

Moving testing to the bedside removes transport delay and introduces operator variability and weaker quality control, which changes rather than removes the error risk.

Where people go wrong

Assuming bedside testing is simply faster.

Turn it into a study

Compare error types for laboratory and bedside glucose testing.

Glucose meters are not diagnostic

Bedside glucose meters have wider permitted error than laboratory methods, which is why diabetes is not diagnosed from a meter reading.

Where people go wrong

Diagnosing diabetes from a glucometer value.

Turn it into a study

Compare meter and laboratory glucose in paired samples.

Rapid tests trade accuracy for speed

Rapid diagnostic tests for malaria, HIV and other conditions sacrifice some for immediacy, which is the right trade when treatment follows immediately.

Where people go wrong

Reading a rapid test as equivalent to a laboratory assay.

Turn it into a study

Compare rapid and laboratory results for one condition.

The rapid test that stopped working

Malaria rapid tests detecting one antigen began to fail where parasites with the gene deleted spread, which is a diagnostic test defeated by evolution.

Where people go wrong

Assuming a validated test remains valid indefinitely.

Turn it into a study

Review the gene deletion problem in malaria rapid testing.

Blood banking is a cold chain

Blood components have different storage temperatures and shelf lives, and a single excursion makes a unit unusable, which makes monitoring continuous rather than periodic.

Where people go wrong

Treating blood storage as refrigeration.

Turn it into a study

temperature monitoring in your blood bank.

Component separation multiplies one donation

Separating a donation into red cells, plasma and platelets allows one donor to treat several patients, each receiving only what they need.

Where people go wrong

Transfusing whole blood where components are available.

Turn it into a study

Review component preparation rates in your blood bank.

Voluntary donation is safer than replacement

Blood from voluntary unpaid donors carries lower infection rates than from replacement or paid donors, which makes donor recruitment a safety intervention.

Where people go wrong

Meeting demand through replacement donation.

Turn it into a study

Measure voluntary donation share in your blood bank.

Cross-matching has been partly replaced

Electronic issue using validated antibody screening can replace serological cross-matching for eligible patients, which shortens issue time substantially.

Where people go wrong

Assuming every unit requires a serological cross-match.

Turn it into a study

Review eligibility for electronic issue in your blood bank.

Wrong blood in tube is the critical error

A sample labelled with the wrong patient's details produces a correct test on the wrong patient, which transfusion systems guard against with bedside identity checks.

Where people go wrong

Relying on laboratory checks to catch identity errors.

Turn it into a study

bedside identity verification at sampling.

Histopathology turnaround depends on processing

Fixation, processing, embedding and staining each take defined time, which sets the floor on turnaround regardless of reporting speed.

Where people go wrong

Attributing slow histology reports to the pathologist.

Turn it into a study

Map the steps and times in your histopathology workflow.

Fixation quality decides what can be done

Inadequate or delayed fixation destroys tissue architecture and antigens, which makes subsequent immunohistochemistry and molecular testing unreliable.

Where people go wrong

Treating fixation as preservation rather than preparation.

Turn it into a study

time from removal to fixation in your specimens.

Cold ischaemia time affects molecular tests

The interval between removing tissue and fixing it degrades nucleic acids and proteins, which matters increasingly as molecular testing becomes routine.

Where people go wrong

Recording no time for specimen handling.

Turn it into a study

Record cold ischaemia times for specimens going to molecular testing.

Immunohistochemistry needs controls

Every immunohistochemical run requires positive and negative controls, because a negative result without a control cannot be distinguished from a failed reaction.

Where people go wrong

Reporting a negative stain without control verification.

Turn it into a study

control use in your immunohistochemistry runs.

Cytology screening needs adequate sampling

A cervical or fine needle sample reported as inadequate is a sampling failure rather than a negative result, and adequacy criteria exist to force the distinction.

Where people go wrong

Reading an inadequate sample as reassuring.

Turn it into a study

Measure inadequacy rates by sampler in your laboratory.

Liquid-based cytology changed the smear

Collecting cells into fluid rather than smearing onto a slide reduced inadequate samples and allowed molecular testing from the same sample.

Where people go wrong

Assuming collection method does not affect the result.

Turn it into a study

Compare inadequacy rates between methods locally.

Molecular testing moved into the laboratory

Polymerase chain reaction and sequencing have moved from research into routine diagnostics, which requires contamination control and interpretation expertise rather than only equipment.

Where people go wrong

Treating molecular testing as another analyser.

Turn it into a study

Review contamination control in your molecular laboratory.

Contamination is the molecular laboratory's enemy

Amplified product contaminating a laboratory produces false positives indefinitely, which is why workflow is unidirectional and areas are separated.

Where people go wrong

Running molecular tests in a shared space.

Turn it into a study

workflow separation in your molecular laboratory.

Sequencing produces variants of uncertain significance

Genetic testing frequently finds variants whose meaning is unknown, which creates a counselling problem rather than a diagnosis and requires reclassification over time.

Where people go wrong

Reporting an uncertain variant as a finding.

Turn it into a study

Review how uncertain variants are reported in your laboratory.

Radiographers position and protect

Image quality and patient dose depend on positioning, collimation and exposure factors chosen by the radiographer, which makes them a determinant of .

Where people go wrong

Treating radiography as operating a machine.

Turn it into a study

Relate image rejection rates with positioning in your department.

Repeat exposures are a dose audit

Rejected and repeated images double the dose for no diagnostic gain, and a reject analysis programme identifies the correctable causes.

Where people go wrong

Repeating an image without recording why.

Turn it into a study

Run a reject analysis for one month in your department.

Collimation reduces dose and improves image

Restricting the beam to the area of interest reduces patient dose and scatter, which improves contrast at the same time.

Where people go wrong

Using a wide field for convenience.

Turn it into a study

collimation practice on your radiographs.

The radiographer's dose is occupational

Staff dose depends on distance, shielding and time, and the inverse square law means a step backward halves exposure far more effectively than extra lead.

Where people go wrong

Relying on an apron rather than distance.

Turn it into a study

Measure dose at different distances during fluoroscopy.

Operating theatre technicians manage the environment

Theatre sterility, equipment readiness and instrument accounting depend on the technician's systems, and failures appear as cancelled lists and retained instruments.

Where people go wrong

Treating theatre support as unskilled work.

Turn it into a study

instrument count documentation in your theatres.

Instrument counting prevents retained items

A formal count before, during and after an operation is what prevents retained instruments and swabs, and the count must be documented and reconciled.

Where people go wrong

Counting informally at the end.

Turn it into a study

count documentation and discrepancy handling.

Dialysis technicians manage water

Water for dialysis requires treatment to standards stricter than drinking water, because a patient is exposed to hundreds of litres a week across a membrane.

Where people go wrong

Treating dialysis water as plumbing.

Turn it into a study

Review water quality testing records in your dialysis unit.

Reuse of dialysers has rules

Where dialysers are reused, cleaning, testing and documentation requirements apply, and failures cause infection and inadequate dialysis.

Where people go wrong

Reusing without documented testing.

Turn it into a study

dialyser reuse documentation in your unit.

Optometrists detect disease

Refraction, pressure measurement and fundus examination by optometrists detect glaucoma, retinopathy and tumours, which makes an eye test a health screen.

Where people go wrong

Treating optometry as spectacle prescribing.

Turn it into a study

disease detection rates in your optometry service.

Vision technicians extend eye care

Trained vision technicians in vision centres perform refraction and screening and refer, which has extended eye care into rural India at low cost.

Where people go wrong

Assuming eye care requires an ophthalmologist.

Turn it into a study

Review vision centre coverage in your district.

Audiologists measure what patients cannot describe

Audiometry quantifies hearing loss by frequency and type, which no history can do, and it is the basis of every management decision in hearing loss.

Where people go wrong

Managing hearing loss on history alone.

Turn it into a study

audiometry availability and use in your hospital.

Speech and language therapy covers swallowing

Speech therapists assess and manage swallowing as well as communication, and swallowing assessment prevents aspiration pneumonia after stroke.

Where people go wrong

Treating speech therapy as communication only.

Turn it into a study

swallow assessment provision after stroke locally.

Perfusionists run the circulation

During cardiac surgery the perfusionist operates the machine that replaces heart and lung function, managing flow, gases, temperature and anticoagulation.

Where people go wrong

Treating cardiopulmonary bypass as equipment.

Turn it into a study

Review the perfusionist's decisions during one case.

Emergency medical technicians make the first decisions

Pre-hospital technicians decide on airway management, immobilisation, destination and pre-notification, which shapes everything that follows in hospital.

Where people go wrong

Treating pre-hospital care as transport.

Turn it into a study

Review pre-hospital decisions in your trauma admissions.

Allied health workforce planning is neglected

Health workforce planning concentrates on doctors and nurses while laboratory, radiography, therapy and technician cadres determine whether services function.

Where people go wrong

Planning services by medical and nursing numbers.

Turn it into a study

Count allied health staff per population in your district.

Allied health regulation arrived late in India

A national commission for allied and healthcare professions was established only in 2021, which means registration, standards and scope for many cadres are still being defined.

Where people go wrong

Assuming all health professions have established regulation.

Turn it into a study

Review which cadres the commission covers.

Task sharing works with structure

Trained non-specialist cadres deliver anaesthesia, surgery, eye care and mental health treatment safely where training, supervision and scope are defined.

Where people go wrong

Opposing or adopting task sharing without the structure.

Turn it into a study

Review a task sharing programme's supervision arrangements.

Simulation trains technical skills safely

Allied health procedures from venepuncture to ventilator management are learned on simulators, which separates skill acquisition from patient risk.

Where people go wrong

Learning technical procedures on patients first.

Turn it into a study

Review simulation provision for allied health training locally.

Competency assessment beats course completion

Observed structured assessment of a specific task demonstrates competence, which a certificate of attendance does not.

Where people go wrong

Certifying competence from course attendance.

Turn it into a study

Design an observed assessment for one technical skill.

Molecules for MNR University: Clinical Research, Medical & Health Sciences
The proteins behind these concepts are in the 3D Lab, where every one can be turned in 3D. Open the molecules for MNR University: Clinical Research, Medical & Health Sciences →

Study ideas for MNR University: Clinical Research, Medical & Health Sciences

Built from what this department works on. Take one to your guide before you collect anything.

SurveyPrevalence of anaemia and its associated factors among undergraduate female students in a medical collegeDesign: Why it is worth doing here: A single haemoglobin estimate answers a question that matters to the group itself.You would need: , a , a validated tool, and written consent from every participant.Start it in the Research guide
SurveySleep quality and academic performance among undergraduate medical students in a medical college: a cross-sectional studyDesign: Why it is worth doing here: Validated scales, a population at hand, and no equipment needed.You would need: , a , a validated measurement tool, and written consent from every participant.Start it in the Research guide
SurveyPrevalence of needle-stick injury and its associated factors among interns in a teaching hospitalDesign: Why it is worth doing here: Common, under-reported and preventable.You would need: , a , a validated tool, and written consent from every participant.Start it in the Research guide
SurveyKnowledge, attitude and practice regarding basic life support among undergraduate medical students in a medical collegeDesign: Why it is worth doing here: A checklist assessment before and after training makes a complete study.You would need: , a questionnaire piloted on ten respondents and scored in advance, and written consent.Start it in the Research guide

Looking at another subject? Every subject is open to everyone, and a concept read through two departments is the fastest way to see how they join. Browse the other 37 subjects.